EAR/23-24/KISEM/IITGN-01/Rev-01(25/07/2023)

The subject plant is located in Ahmedabad district of Gujarat and falls under NIC Category-37003. This assessment was carried out by the IEAC Center, IIT Gandhinagar, during the course of the year 2023.

General Info

Principal Product

Common Effluent Treatment Plant

Plant Area (Sq.ft)

30,000

No. of Employees

45

Production Hours

7,200

Annual Production

Annual Sales

₹1,00,00,000

Assessment Summary

Total Energy Costs(per year)

₹2,04,43,743

Total Recommended Investment(one time)

₹11,00,000

Total Recommended Savings(per year)

₹24,04,725

Energy Costs Calculation
Electricity

Annual Usage

20,81,870

Unit

kWh

Unit Cost

₹9.81

Annual Cost

₹2,04,43,743

Total Energy Costs(per year)

₹2,04,43,743

Observations & Recommendations
PP - Pumps
ObservationRecommendationUnit SavingsAnnual SavingsInvestmentROIStatus
Some of the sludge transfer pumps(2& 6) running under loadClean NRV and impeller along with casing and also check impeller diameter
Some of the sludge transfer pumps(2& 6) running under loadUse VFD for both pumps with pressure transmitter/transducer68,031₹6,12,281₹2,00,0004
Bypassing the flow due to increase in the inlet pressure of Filter press (calculation excludes for pump 2 & 6., Filter press 1 & 4)Use VFD with Filter press pump and take input from Pressure transducer for controlling motor speed. (Rated power=30 kW) and if any spare impeller is available replace with pump 4 and run on VFD1,02,047₹9,18,421₹3,00,0004
Lime Transfer pump 7A & 7B are running under loadCheck the impeller size, any choking near NRV and impeller casing. After cleaning ,check the flow ,pressure and current, if no choking found replace with smaller pump
Recycling pumps of 14 A & B are running under load and on Efficiency of 66% while the design efficiency of pump is 70%.(Running time for all the pumps are considered as 24 hrs of operation for 360 day )Use VFD with motor and pump so that efficiency will increase7,603₹68,429₹1,50,00024
Recycling pumps 0f 15 A & B are running under load and on Efficiency of 54% while the design efficiency of pump is 70%.(Running time for all the pumps are considered as 24 hrs of operation for 360 day )Use VFD with motor and pump so that efficiency will increase39,830₹3,58,474₹1,50,0005
All recycling pumps of 16 are running under load and on Efficiency of 55-60% while the design efficiency of pump is 70%.(Running time for all the pumps are considered as 24 hrs of operation for 360 day )Use VFD with motor and pump so that efficiency will increase32,400₹2,91,600₹1,50,0006
All recycling pumps 0f 16 are running under load and on Efficiency of 55-60% while the design efficiency of pump is 70%.(Running time for all the pumps are considered as 24 hrs of operation for 360 day )Use VFD with motor and pump so that efficiency will increase17,280₹1,55,520₹1,50,00012
Transfer pump running under load (Rated power=37 kW and Actual Power= 27 kW)Replace the motor with 30 kW